Sign in
Corporate calculators measure an organization over a year, which makes a project invisible. This one gives an indicative estimate of the carbon of delivering a project, the carbon of what it hands over across its service life, and the carbon it avoids against a reference scenario you declare. Three figures, reported separately, in the shape a gate decision needs.
| Project | Template | Delivering | Running | Avoided (separate) |
|---|---|---|---|---|
| Your first project | Infrastructure and construction | ... | ... | ... |
| Next project | ... | ... | ... | ... |
| Portfolio total | ... | ... | ... |
Saved projects stay with your account, each frozen with the factor set it was calculated with, so a figure reproduces exactly after the annual refresh.
A project has two footprints and one comparison. The first footprint is the carbon of delivering it, spent once and largely fixed by decisions taken at design and procurement. The second is the carbon of what the project hands over, which repeats every year of the service life. The comparison is what the handover avoids against a reference scenario you declare, and it is reported on its own. Nothing is netted, because avoided emissions belong to a different accounting system from emissions and the WBCSD Guidance on Avoided Emissions v2.0 requires them to be kept apart.
The structure uses the capital, operational and user carbon terminology of PAS 2080:2023 for built assets. Lines are organised so an organization can allocate them to scopes under the GHG Protocol Corporate Standard, including scope 3 category 2, capital goods. The boundary and reference scenario concepts are informed by ISO 14064-2:2019 and the GHG Protocol for Project Accounting; the tool produces an ex ante estimate and does not include the baseline candidate analysis, monitoring plan or independent verification those standards require for a claimable reduction.
Results can inform an entity\'s actions and resources disclosure under ESRS E1-3 (E1-5 from FY2027) and its consideration of IF-EN-160a.2 and IF-EN-410a.2 (Engineering and Construction Services: construction phase risks including emissions to air, and operational phase energy efficiency in project planning and design) or TC-SI-130a.3 (Software and IT Services: environmental considerations in strategic planning for data center needs), metrics in the SASB Standards version 2023-12 maintained by the ISSB, which entities applying IFRS S2 are required to refer to and consider. They are not for the gross scope 1, 2 and 3 disclosure, not for EU Taxonomy alignment and not for assurance. The tool is not affiliated with, licensed by or endorsed by the IFRS Foundation, the SBTi, BSI, ISO or the GHG Protocol.
Confidence is the share of the figures resting on national or standard body factors, weighted by how much each line contributes. A high figure with low confidence is a research task. A low figure with high confidence is a result. Every saved project keeps the factor set it was calculated with, so a run reproduces exactly after the factors are refreshed each year.
| Factor | kgCO₂e | Per | Source and edition | Year | License | GWP basis | Confidence |
|---|---|---|---|---|---|---|---|
| grid_GB | 0.131 | kWh | DESNZ UK Government GHG Conversion Factors 2026, grid average including imports | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| grid_US | 0.3497 | kWh | US EPA eGRID2023, national average, 770.9 lb CO2e per MWh | 2025 | US Government, public domain | AR5 | high |
| grid_IN | 0.71 | kWh | CEA CO2 Baseline Database v21.0, weighted average, CO2 only | 2025 | Government of India | CO2 only, not CO2e | high |
| grid_CA | 0.191 | kWh | Ember Global Electricity Review 2026 data, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| grid_EU | 0.21 | kWh | Ember Global Electricity Review 2026, EU-27, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| grid_FR | 0.041 | kWh | Ember Global Electricity Review 2026 data, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| grid_CN | 0.525 | kWh | Ember Global Electricity Review 2026, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| grid_JP | 0.477 | kWh | Ember Global Electricity Review 2026, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| grid_AU | 0.525 | kWh | Ember Global Electricity Review 2026 data, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| grid_BR | 0.11 | kWh | Ember Global Electricity Review 2026, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| grid_XX | 0.458 | kWh | Ember Global Electricity Review 2026, world average, 2025 | 2026 | CC BY 4.0 | AR5, upstream CH4 at 21 | moderate |
| concrete | 246 | m3 | MPA and BRMCA generic UK ready-mixed concrete EPD (IBU 2018), 35 percent cement replacement; corroborated by IStructE 2020 at 0.103 kgCO2e per kg | 2018 | EPD facts, cited | AR4 (EN 15804+A1) | moderate |
| rebar_eaf | 684 | t | BRC reinforcement EPD 2019 via IStructE 2020, UK electric arc furnace, about 97 percent recycled | 2020 | EPD facts, cited | AR4 (EN 15804+A1) | moderate |
| steel_bof | 2,450 | t | British Steel sections EPD 2020 via IStructE 2020, UK basic oxygen route | 2020 | EPD facts, cited | AR4 (EN 15804+A1) | moderate |
| steel_eu | 1,130 | t | Bauforumstahl European average sections via IStructE 2020 | 2020 | EPD facts, cited | AR4 (EN 15804+A1) | moderate |
| asphalt | 57 | t | NAPA SIP-109 (2024), US industry average hot mix, 51.4 kgCO2e per short ton; UK EPD pending | 2024 | Published facts, cited | Not stated by the publisher | illustrative |
| aggregate | 5.77 | t | Aggregate Industries Torr Works crushed limestone EPD, BRE Global 2018; indicative pending a current EPD | 2018 | EPD facts, cited | AR4 (EN 15804+A1) | moderate |
| timber | 126 | m3 | IStructE 2020, certified sawn softwood, 0.263 kgCO2e per kg at 480 kg per m3, sequestration excluded | 2020 | Published guide, cited | AR4 (EN 15804+A1) | moderate |
| diesel | 2.584 | litre | DESNZ 2026, combustion only, average biofuel blend; well to tank 0.611 reported separately | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| diesel_wtt | 0.611 | litre | DESNZ 2026, well to tank for diesel | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| freight | 0.111 | metric ton-km | DESNZ, all HGVs average laden; 2026 cell to be confirmed | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | moderate |
| car | 0.17 | km | DESNZ 2025, average car; petrol 0.163, diesel 0.173, hybrid 0.128 | 2025 | OGL v3 | AR5 (CH4 28, N2O 265) | moderate |
| air_short | 0.126 | passenger-km | DESNZ 2026, short haul international economy, with radiative forcing (multiplier 1.7) | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| air_long | 0.117 | passenger-km | DESNZ 2026, long haul international economy, with radiative forcing (multiplier 1.7) | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| landfill_inert | 1.23 | t | DESNZ 2026, inert construction waste to landfill | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| landfill_mixed | 467.05 | t | DESNZ 2026, mixed commercial and industrial waste to landfill | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| recycled | 21.29 | t | DESNZ 2026, closed loop recycling | 2026 | OGL v3 | AR5 (CH4 28, N2O 265) | high |
| paper | 0.0067 | sheet | DESNZ 2024, paper primary production, 1,339 kgCO2e per metric ton at 4.99 g per A4 sheet | 2024 | OGL v3 | AR5 (CH4 28, N2O 265) | moderate |
| fte_month | 80 | FTE-month | GPM working assumption: office energy and commuting per person-month | 2026 | GPM | Not applicable (GPM assumption) | illustrative |
| fte_year | 960 | FTE-year | GPM working assumption: office energy and commuting per person-year | 2026 | GPM | Not applicable (GPM assumption) | illustrative |
| laptop | 200 | unit | Dell Latitude 5450 LCA 2024 and comparable manufacturer PCFs, embodied share; range 180 to 300 | 2024 | Manufacturer facts, cited | Not stated by the publisher | moderate |
| monitor | 120 | unit | Dell P2425H LCA 2024, 24 inch, embodied share of 155 whole life | 2024 | Manufacturer facts, cited | Not stated by the publisher | moderate |
| phone | 30 | unit | Apple iPhone 17 Product Environmental Report 2025, production share of 55 to 61 whole life | 2025 | Manufacturer facts, cited | AR6 | moderate |
| server | 816 | unit | Dell PowerEdge R6725 PCF 2025, manufacturing and transport; stated uncertainty exceeds the value | 2025 | Manufacturer facts, cited | Not stated by the publisher | illustrative |
| device_kwh | 50 | device-year (kWh, priced at the grid factor) | GPM working assumption: 50 kWh of electricity per end user device per year, converted with the grid factor for the country | 2026 | GPM | Follows the grid factor of the country selected | illustrative |
| cloud_spend | 0.5 | currency unit | Spend based proxy for cloud services; use only when metered energy is unavailable | 2026 | GPM | Not applicable (GPM assumption) | illustrative |
| q_road | 500 | million | Capital carbon intensity, published civils benchmarks | 2025 | GPM synthesis | Not applicable (GPM assumption) | illustrative |
| q_rail | 450 | million | Capital carbon intensity, published civils benchmarks | 2025 | GPM synthesis | Not applicable (GPM assumption) | illustrative |
| q_water | 350 | million | Capital carbon intensity, published civils benchmarks | 2025 | GPM synthesis | Not applicable (GPM assumption) | illustrative |
| q_building | 400 | million | Capital carbon intensity, published building benchmarks | 2025 | GPM synthesis | Not applicable (GPM assumption) | illustrative |
| q_energy | 380 | million | Capital carbon intensity, published civils benchmarks | 2025 | GPM synthesis | Not applicable (GPM assumption) | illustrative |
| q_software | 45 | million | Delivery carbon intensity of software programs, working assumption | 2026 | GPM | Not applicable (GPM assumption) | illustrative |
| q_infra_it | 90 | million | Delivery carbon intensity of infrastructure-heavy IT, working assumption | 2026 | GPM | Not applicable (GPM assumption) | illustrative |
The GWP basis column names the IPCC assessment report each publisher used to convert methane and nitrous oxide into carbon dioxide equivalent. This tool applies no global warming potential of its own, so the equivalence is inherited from the factor. Where a publisher states no basis, the column says so rather than assuming one.
Material factors are stated in kilograms of CO₂e per unit and converted to metric tons in the result. Grid factors are applied to every electricity line, including the ones inside the handover phase, so a project delivered in a country with a cleaner grid shows a lower operational figure, which is what happens in practice.